header-logo

Stage-specific carbon, thermal and cost analysis of reinforced-concrete wet-wall and high-insulation steel-stud drywall systems

주 저자Kwonye Kim, Youngsik Kwon, Youngdong Yu, Jae-Weon Jeong, Yujin Nam
공동 저자-
소속-
AbstractThe construction industry requires wall systems that reduce construction- and operation-stage impacts, yet studies often compare wet and dry systems with unequal thermal properties or examine thermal bridges without integrating energy, carbon, and cost. This study applied a stage-specific carbon, thermal, and cost comparison to a reinforced-concrete (RC) wet wall, conventional C-stud drywall, and proposed high-insulation slotted steel-stud drywall using TRISCO (Physibel, Ghent, Belgium), TRNSYS 18, life-cycle inventory data, and 60-year present-value sensitivity. For the evaluated opaque non-load-bearing walls, the proposed system had reported emissions of 225.9 kg CO2-eq/m2 from material production through on-site construction, 49.5% below the selected RC wall and a reported 4.1% below conventional drywall (percentage reconciliation is discussed in Section 4.3); on-site construction emissions decreased from 36.0 to 18.0 kg CO2-eq/m2. At an equal U-value of 0.170 W/(m2·K), its 240 mm thickness was 38.9% below the 392.5 mm RC wall and 14.3% below the 280 mm conventional drywall. Reported annual heating-and-cooling energy consumption was 72.63 kWh/(m2·yr), 11.1% below the RC operational reference and 8.9% below conventional drywall. Operational emissions calculated using simulation-derived energy use and emission factors provided by the Ministry of Environment, Republic of Korea, on a 2021 CO2-equivalent basis, were reported as 13.5 kg CO2-eq/(m2·yr), compared with 29.5 for RC and 16.6 for conventional drywall. Across real discount rates of 0–5% under constant 2023 real prices, the proposed system’s scenario-based 60-year present-value cost was 13.3–13.7% below the RC wall. Wet-to-dry substitution was the primary upfront-carbon measure; stud optimization provided a smaller additional improvement. The assessment covers climate change only. Operational normalization and energy-to-carbon/cost links remain unverified; maintenance and replacement are excluded from the cost scenario. Conclusions remain configuration-specific and do not establish a reconciled whole-life benefit or structural-safety certification.
KeywordSustainable construction, Drywall; Steel studs, Carbon emissions, Life-cycle carbon assessment
페이지pp. 1~9
논문 파일 없음
게재일시 2026-12
DOIhttps://doi.org/10.1016/j.seta.2026.105600
학회/저널명Sustainable Energy Technologies and Assessments Vol.96, No.105600
년도2026
추가 문구https://doi.org/10.1016/j.seta.2026.105600
등록 일시2026-11-22 10:14:22