Abstract The applicability and economic feasibility of thermoelectric technology to prevent condensation that can occur at thermal bridges in buildings was analyzed through steady-state heat transfer analysis using THERM 7.8 and energy consumption analysis using thermoelectric element regression equations. The annual energy was analyzed to be a maximum of 70.17 kWh per household, and when converted to electricity costs, it was calculated to be approximately 8,420 won. By applying thermoelectric technology, which can respond quickly and flexibly in a variety of environments, to the anti-condensation system, excellent effects were achieved in both environmental and economic aspects.
KeywordThermal bridge, Anti-condensation system, Thermoelectric technology, Peltier effect
페이지pp. 365~366
논문 파일 없음
게재일시 2024-04
DOI-
학회/저널명대한건축학회논문집 Vol.44, No.1
년도2024
추가 문구-