Abstract | This study empirically investigates the winter operating performance of a liquid-desiccant system integrated with a heat pump compared to a conventional heating and humidification system, consisting of an energy recovery ventilator, electric heat pump, and evaporative humidifier. The proposed system achieves 95% indoor thermal comfort satisfaction, primarily attributed to its superior humidification performance. Thus, the proposed system is estimated to save operating energy consumed to maintain indoor thermal comfort for an hour by 16.5% through the recovery of waste heat from the condensation heat of the heat pump. |