Abstract | In this study, a building-integrated photovoltaic panel incorporating a thermoelectric generator and a phase change material annual performance was analyzed to enhance the efficiency of the existing solar panel and harvest solar heat, which can reduce the efficiency of the PV panel. The experiment was conducted from March to July, and through this, the annual pattern and power generation amount were identified. As a result of the experiment, the power generation was about 3.7
W/m2 in March, and the power generation was 1 W/m2, which was about 4 times less, in July. |